IBM Rational Team Concert
Technical requirements
The following requirements must be met to integrate Rational Team Concert (RTC) with SD Elements.
-
Basic Authentication or Forms Authentication should be enabled on RTC
-
The user configured for the connection should:
-
Be a member of the project
-
Have permission to create, tag, transition and close work items.
-
Specific permissions:
-
JazzUsers Repository Permission
-
-
Default assigned fields
The following fields are set by default:
-
Summary
-
Description
-
Tags
-
Priority
Behavior
The integration supports the following:
-
One-way status synchronization. The integration currently only supports synchronizing status from RTC tasks to SD Elements
Connection details
Enter the connection details for the server.
Protocol |
Select the protocol for the connection (HTTPS or HTTP) (Default: HTTPS) |
---|---|
Server |
The domain name or IP address of the server |
Context Root |
Top-level location where RTC is installed on a server. The value for this may be dependent on the configuration of an internal corporate proxy or where an administrator has installed RTC. |
Credentials
Enter the credentials needed to authenticate to the server.
Username |
Username authorized to connect with the server. This user should be able to create and edit stories/issues in RTC. |
---|---|
Password |
The password used to authenticate to the server |
Project details
Enter the project-level details.
Rational Project |
The name of the project where issues should be created. |
---|
Advanced Rational Team Concert configuration
Enter advanced configuration options.
Issue Type |
The name of the issue type to create in RTC (Default: task) |
---|---|
States which map to DONE in SD Elements: |
Comma-separated list of states in RTC that will be mapped to DONE in SD Elements. (Default: |
Synchronization
Enter settings for synchronizing SD Elements tasks.
Authoritative Source |
The SD Elements task will be updated to match the status in RTC. Two-way status sync is not presently supported. |
---|---|
Include code sample How-To’s in task descriptions |
Whether or not to include detailed code samples and How-To’s in the RTC issue. |
This server is not accessible from the SD Elements server |
Select this option if SD Elements does not have direct network access to the RTC server. For example, if you are using a hosted SD Elements instance but you want to integrate with an internal/protected RTC system, choose this option and run the Remote Integration Client to perform integration. |
Tasks to synchronize
Select the SD Elements tasks that are synchronized with the RTC project.
Tasks having a minimum priority |
Synchronize tasks with a minimum priority (for example, 7 or above). This is useful if you want to limit the amount of work for users. (Default: 7) |
---|---|
Tasks with status |
Synchronize only tasks with certain statuses, such as TODO or DONE. (Default: TODO) |
Tasks having phase |
Synchronize only tasks in certain phases, such as Requirements or Development. (Default: Requirements, Architecture & Design, Development) |
Tasks having all of the following tags |
Synchronize only tasks containing certain SD Elements task tags. (Optional) |
Tasks with verification status |
Synchronize only tasks with a specific verification status, such as Pass or Fail. (Default: None, Partial Pass, Pass, Fail) |
Advanced ALM options
Enter advanced configuration options.
ALM context |
Bind a set of tasks using a cetain value. This is applicable only when custom titles are selected having the entry "Context" |
||
---|---|---|---|
Custom Priority Mapping |
If the standard RTC priorities have been customized, you must map the customized priority names in RTC to their corresponding SD Elements numeric priorities.
For example, map "P1" issues to priorities |
||
Custom Fields Mapping |
In addition to the default-assigned fields, you can map additional SD Elements fields to RTC fields.
For example, you may have a required field in your RTC project that is not set by default. Custom field mappings can be set at both the system connection and project connection levels, and that mappings set in a project connection will override mappings set in the system connection. For more details refer to section Advanced field support. To assign values to fields having hierarchy, such as Filed Against and Planned For, use the / character to denote levels. Consider the following values for Filed Against, To assign the value "Team 2 (rename)" to Filed Against, create a new mapping with |
Sync frequency
Select how frequently the SD Elements and RTC projects are synchronized. You can choose from the following options. The more frequently you run synchronization, the greater the performance impact on both the SD Elements and RTC servers. This is generally only a concern for large organizations running many synchronizations at once.
Hourly, Daily, Weekly, or Monthly |
The projects will synchronize automatically every hour, day, week or month. Daily synchronization is typically sufficient. However, you may want to select a more frequent interval if development moves quickly in your organization. |
---|---|
Manually |
You must click the Sync button on the ALM Integrations page in order to synchronize the projects. This is the default value. |